(ACS) Aluminum Clad Steel Wires

Construction                                                          

Aluminum-clad steel wire, commonly abbreviated as AW or AS or AC, is an electrical conductor composed of an inner steel core and outer Aluminum cladding. Aluminum clad steel wire is a bimetallic in which aluminum covers on the steel core continuously and evenly.

Advantages                                                           

Aluminum-clad steel wire is superior to galvanized or aluminized steel in every way. 

● Better corrosion resistance due to thick EC-grade aluminum covering 

● Wider range of combinations of tensile strength and conductivity 

● Lighter weight 

● Excellent thermal stability 

● Wider variety of products, with broad range of properties, quality, and size of steel wire and aluminum cladding. 

● Compared with ordinary aluminum conductor steel reinforced, the conductor weight is 5% lighter, current-carrying capacity is 2-3% higher and power loss decreases 4-6%. Thus, the service life is long and it adds none erection cost.

 

Application                                                             

The aluminum clad steel wire is widely used in long-span transmission line, coastal areas and island as well as other hot and humid regions, salt fog regions and heavily polluted regions where the high corrosion resistance strand is needed.

 

It is used as the core of ACSR/AW, overhead ground conductor, extra high voltage overhead conductor, optical fiber composite overhead ground line, self-damping conductor line, bare overhead conductor, OPGW, ground wire, messenger wire, guy wire formed wire for protecting, terminating and splicing transmission and distribution lines, fence, barber wire and hardware, etc.

 

Standards                                                                  

IEC 61232, ASTM B415, ASTM B502, AS 3607 and other International Standards.

However, can also supply a range of alternative designs with customized solutions to meet customer requirements.

Abbreviations                                                          

AW : Aluminum-clad steel wire as per ASTM B 502 Standard. 

AS : Aluminum-clad steel wire as per IEC 61232 Standard. 

AC : Aluminum-clad steel wire as per AS 3607 Standard.

 

 

 

 

 

 

 

Classification of Aluminum Clad Steel wires                                    

Class

14% 

IACS

20.3% IACS A

20.3% IACS B

23

IACS

27

IACS

30% 

IACS

35%

 IACS

40% IACS

Sectional Ratio of Al (%)

13

25

25

30

37

43

52

62

Sectional Ratio of St (%)

87

75

75

70

63

57

48

38

Weight Ratio of AL (%)

5

10.4

10.4

12.9

16.9

20.7

27.3

36.1

Weight Ratio of ST (%)

95

89.6

89.6

87.1

83.1

79.3

72.7

63.9

Physical Constants                                                       

Class

14%

IACS

20.3%

IACS A

20.3%

IACS B

23%

IACS

27%

IACS

30%

IACS

35% IACS

40% IACS

Nominal Density at 20°C (g/cm3 )

7.14

6.59

 

6.59

6.27

 

5.91

 

5.61

 

5.15

4.64

Final Modulus of Elasticity (Gpa)

170

162

 

155

149

 

63

132

 

122

 

109

Coefficient of Linear Exp. (per °C)

12 x 10-6

13 x 10-6

 

12.6 x 10-6

12.9x10-6

13.4 x 10-6

13.8 x10-6

 

14.5 x 10-6

 

15.5 x 10-6

 

Temperature coefficient (per °C)

0.0034

 

0.0036

 

0.0036

 

0.0036

 

0.0036

0.0038

 

0.0039

 

0.004

 

% Elongation at Fracture on 250mm

1.5

 

1.5

1.5

1.5

1.5

1.5

1.5

1.5

 

The design of an aluminum-clad steel wire with a specified conductivity is based on 61 % IACS of aluminum and 9 % IACS of steel. For example, the conductivity of 30% IACS is dealt with as follows: Designed conductivity: Aluminum (61 % IACS x 0.43) + Steel (9 % IACS x 0.57) = 31.36 % IACS. Then, taking into consideration allowances, minimum conductivity is specified as 30 % IACS (57.47 nΩm). When only the aluminum covering is taken into account as the conductive part in the conductor, the electrical resistance of aluminum-clad steel wires can be calculated by the cross-sectional area of aluminum as per above and the conductivity of 61 % IACS. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifications for Aluminum Clad Steel Wires (Before Stranding)

 

Class

Type

Nominal Diameter

(mm)

Min Tensile Strength (MPa)

 

Min stress at 1 % elongation (MPa)

 

Max. Resistivity at Over 20°C (nΩ∙m)

 

 

 

 

 

14%1ACS

 

over

Upto & Including

 

A

1.24

3.0

1590

1410

123.5

3.0

3.5

1550

1380

3.5

4.75

1520

1380

4.75

5.5

1400

1200

B

2.1

4.0

1770

1550

 

 

 

 

20%1ACS

 

 

1.24

3.25

1340

1200

 

 

 

 

84.80

3.25

3.45

1310

1180

3.45

3.65

1270

1140

3.65

3.95

1250

1100

3.95

4.1

1210

1100

4.1

4.4

1180

1070

4.4

4.6

1140

1030

B

4.6

4.75

1100

1000

23%1ACS

 

2.50

5.00

1220

980

74.96

27%1ACS

 

2.50

5.00

1080

800

63.86

30%1ACS

 

2.50

5.00

880

650

57.47

35%1ACS

 

A

2.50

5.00

810

590

49.26

 

B

2.50

5.00

880

650

40%1ACS

 

A

2.50

5.00

680

500

43.10

B

2.50

5.00

750

550

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SINGLE WIRE AS PER ASTM B 415 STANDARD

Size

 AWG

 

Diameter

 

Tensile

Strength

 

Cross 

section

 

D C Resistance 

at 20°C

 

Nominal

Weight

 

Minimum Thickness of Aluminum Cladding

 

in.

mm

ksi

 

N/mm²

 

in²

 

mm²

 

Ω/km

 

lb/1000 ft

 

Kg/km

 

in

 

mm

 

( CONDUCTIVITY = 20.3 % IACS)

4.0

0.204 

5.189 

 155 

 1070 

0.03278 

 21.149 

4.010 

93.67 

 139.37 

0.01022 

 0.259

0.188 

4.775 

 160 

1100 

0.02776 

17.909 

 4.735 

79.32 

118.02 

0.00940 

0.239

5.0

0.182 

4.620 

 165 

 1140 

0.02599 

16.766 

 5.058 

74.25 

110.49 

0.00910 

0.231

0.173 

4.392 

 170 

1170 

0.02348 

15.148 

 5.598 

67.09 

99.82 

0.00865 

 0.220

6.0

 

0.162 

4.115 

 175 

1210 

0.02061 

13.298 

 6.377 

58.89 

 87.63 

0.00810       

 0.206

0.155 

3.934 

 180 

 1240 

0.01884 

12.158 

 6.975 

 53.84 

 80.12 

0.00775 

 0.197

7.0

0.144 

3.665 

 185 

1280 

0.01635 

10.551 

8.037 

 46.73 

 69.53 

0.00722 

 0.183

0.137 

3.477 

 190 

1310 

0.01472 

9.497 

8.930 

 42.06 

62.58 

0.00685 

0.174

8.0

0.129 

3.264 

 195 

1340 

0.01297 

8.367 

 10.135 

 37.06 

55.14 

0.00643 

 0.163

9.0

0.114 

2.906 

 195 

1340 

0.01028 

6.631 

12.787 

29.37 

43.70 

0.00572 

 0.145

10.0

0.102 

2.588 

 195 

1340 

0.00816 

5.261 

16.117 

23.30 

34.67 

0.0051

 0.129

11.0

0.091 

2.304 

 195 

1340 

0.00646 

4.168 

20.343 

18.46 

 27.47 

0.00454 

 0.115

12.0

0.081 

2.052 

 195 

1340 

0.00513

3.308 

25.634 

 14.65 

 21.80 

0.00404 

 0.103

CONDUCTIVITY = 27 % IACS)

4.0

0.204

5.189

125

862

0.03278

21.149

3.019

84.00

124.99

0.01430

0.363

0.188

4.775

106

731

0.02776

17.909

3.209

67.52

100.47

0.01410

0.358

5.0

0.182

4.620

110

758

0.02599

16.766

3.428

63.21

94.06

0.01364

0.347

0.173

4.392

114

786

0.02348

15.148

3.794

57.11

84.98

0.01297

0.329

6.0

0.162

4.115

114

786

0.02061

13.298

4.322

50.14

74.60

0.01215

0.309

0.155

3.934

118

814

0.01884

12.158

4.727

45.84

68.21

0.01162

0.295

7.0

0.144

3.665

122

841

0.01635

10.551 5

5.447

39.78

59.19

0.01082

0.275

0.137

3.477

126

869

0.01472

9.497

6.052

35.80

53.28

0.01027

0.261

8.0

0.129

3.264

156

1076

0.01297

8.367

7.632

33.23

49.45

0.00900

0.228

9.0

0.114

2.906

156

1076

0.01028

6.631

9.629

26.34

39.19

0.00801

0.203

10.0

0.102

2.588

156

1076

0.00816

5.261

12.136

20.90

31.10

0.00713

0.181

11.0

0.091

2.304

156

1076

0.00646

4.168

15.319

16.56

24.64

0.00635

0.161

12.0

0.081

2.052

156

1076

0.00513

3.308

19.303

13.14

19.55

0.00566

0.144

CONDUCTIVITY = 30 % IACS)

 

4.0

0.204

5.189

102

703

0.03278

21.149

2.717

79.74

118.65

0.01532

0.389

0.188

4.775

106

731

0.02776

17.909

3.209

67.52

100.47

0.01410

0.358

5.0

0.182

4.620

110

758

0.02599

16.766

3.428

63.21

94.06

0.01364

0.347

0.173

4.392

114

786

0.02348

15.148

3.794

57.11

84.98

0.01297

0.329

6.0

0.162

4.115

114

786

0.02061

13.298

4.322

50.14

74.60

0.01215

0.309

0.155

3.934

118

814

0.01884

12.158

4.727

45.84

68.21

0.01162

0.295

7.0

0.144

3.665

122

841

0.01635

10.551

5.447

39.78

59.19

0.01082

0.275

0.137

3.477

126

869

0.01472

9.497

6.052

35.80

53.28

0.01027

0.261

8.0

0.129

3.264

128

883

0.01297

8.367

6.869

31.54

46.94

0.00964

0.245

9.0

0.114

2.906

128

883

0.01028

6.631

8.666

25.00

37.20

0.00858

0.218

10.0

0.102

2.588

128

883

0.00816

5.261

10.923

19.84

29.52

0.00764

0.194

11.0

0.091

2.304

128

883

0.00646

4.168

13.787

15.72

23.38

0.00680

0.173

12.0

0.081

2.052

128

883

0.00513

3.308

17.372

12.47

18.56

0.00606

0.154

CONDUCTIVITY = 40 % IACS)

 

4.0

0.204

5.189

80

552

0.03278

21.149

2.038

65.95

98.13

0.02554

0.649

0.188

4.775

84

579

0.02776

17.909

2.407

55.85

83.10

0.02350

0.597

5.0

0.182

4.620

88

607

0.02599

16.766

2.571

52.28

77.79

0.02274

0.578

0.173

4.392

92

634

0.02348

15.148

2.845

47.23

70.29

0.02161

0.549

6.0

0.162

4.115

96

662

0.02061

13.298

3.241

41.47

61.70

0.02025

0.514

7.0

0.144

3.665

98

676

0.01635

10.551

4.085

32.90

48.96

0.01804

0.458

0.137

3.477

98

676

0.01472

9.497

4.539

29.61

44.06

0.01711

0.435

8.0

0.129

3.264

99.5

686

0.01297

8.367

5.152

26.09

38.82

0.01606

0.408

9.0

0.114

2.906

99.5

686

0.01028

6.631

6.500

20.68

30.77

0.01430

0.363

10.0

0.102

2.588

99.5

686

0.00816

5.261

8.192

16.41

24.41

0.01274

0.324

11.0

0.091

2.304

99.5

686

0.00646

4.168

10.340

13.00

19.34

0.01134

0.288

12.0

0.081

2.052

99.5

686

0.00513

3.308

13.029

10.32

15.35

0.01010

0.257

SINGLE WIRE AS PER ASTM B 502 STANDARD

 

Diameter

Tensile Strength

Stress at 1% Extension

Resistity

Density

in.

mm

ksi

N/mm2

ksi

N/mm2

 

 

 

 

0.0770 ~ 0.1289

1.956 ~ 3.274

195

1344

175

1206

 

 

 

51.01

 

 

 

84.8

 

 

 

0.2381

 

 

 

6.59

0.1290 ~ 0.1369

3.275 ~ 3.477

190

1310

170

1172

0.1370 ~ 0.1443

3.478 ~ 3.665

185

1275

165

1137

0.1444 ~ 0.1549

3.666 ~ 3.934

180

1241

160

1103

0.1550 ~ 0.1620

3.935 ~ 4.115

175

1206

160

1103

0.1621 ~ 0.1729

4.116 ~ 4.392

170

1172

155

1068

0.1730 ~ 0.1819

4.393 ~ 4.620

165

1137

150

1034

0.1820 ~ 0.1880

4.621 ~ 4.775

160

1103

145

1000

Coefficient of linear expansion Modulus of Elasticity

:  12.6 x 10-6 /°C

:  23500 Ksi (162000 MPa)

Temperature coefficient of Resistance:  0.0036/°C

Minimum Aluminum Thickness : 10% of nominal wire radius

 

 

 

 

 

 

SINGLE WIRE AS PER AS-3607 STANDARD

Diameter(mm)

Tensile Strength

Cross section

D.C Resistance 

at 20

 

Nomial weight

Min.thickness of 

Aluminum cladding

standard

max.

min.

N/mm2

KN

mm2

Ω/km

 

kg/km

in

mm

1.600

1.640

1.560

1340

2.69

2.011

42.28

13.25

0.080

 

1.750

1.790

1.710

1340

3.22

2.405

35.34

15.85

0.088

 

2.250

2.290

2.210

1340

5.33

3.976

21.38

26.20

0.113

 

2.500

2.540

2.460

1340

6.58

4.909

17.32

32.35

0.125

 

2.750

2.791

2.709

1340

7.96

5.940

14.31

39.14

0.138

 

3.000

3.045

2.955

1340

9.47

7.069

12.03

46.58

0.150

 

3.250

3.299

3.201

1340

11.12

8.296

10.25

54.67

0.163

 

3.500

3.553

3.448

1310

12.60

9.621

8.83

63.40

0.175

 

3.750

3.806

3.694

1270

14.03

11.045

7.70

72.78

0.188

 

Coefficient of linear expansion Modulus of Elasticity

:  12.9 x 10-6 /°C

:  23500 Ksi (162000 MPa)

Temperature coefficient of Resistance:  0.0036/°C

Minimum Aluminum Thickness  : 10% of nominal wire radius

 

 

None

Contact Us
  • E-mail: nancy@suntaysteel.com
  • Mobile: 0086-13855514957
  • Tel.: 0086-13155366798
  • Fax: 008613155366798
  • WeChat: 0086-13855514957
  • Skype: nancylsl
  • WhatsApp:0086-13855514957
  • Add.: Lishui Industry Park,Nanjing,Jiangsu,China
  • wechat

    nancy: 0086-13855514957

Chat with Us